Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
3.
Rev. cuba. med. trop ; 65(2): 223-233, abr.-jun. 2013.
Article in Spanish | LILACS | ID: lil-675504

ABSTRACT

Introducción: la finalidad de todo laboratorio de control de la calidad del diagnóstico serológico de sífilis es controlar su correcta realización. Objetivo: evaluar una propuesta de modelo estadístico para tabular los resultados de los laboratorios adscritos al control de la calidad de diagnóstico de serología VDRL (venereal disease research laboratories)/RPR (rapid plasma reagin) para la evaluación y atención diferenciada a estos. Métodos: se elaboró un modelo para la recogida de información de los 21 laboratorios de la red en Villa Clara durante 2006-2010 y se hicieron modificaciones hasta llegar a la versión final. Se definieron las variables sueros enviados, total discordantes, discordantes no reactivas, discordantes reactivas, envío por mes, y evaluación integral. Se establecieron criterios de estimación para cada variable. Se presenta la evaluación del modelo con la información del trimestre enero-marzo de 2011. Resultados: la propuesta permitió detectar que las principales dificultades radican en el no cumplimiento del número de sueros enviados, no se recepcionan muestras mensualmente y además se presentan resultados discordantes. El modelo resulta justo al valorar porque se utilizan criterios cuantitativos generalizados que posibilitan dar una evaluación cualitativa individualizada, y se corresponde con las técnicas evaluativas actuales que se aplican en diferentes esferas del quehacer social. Conclusiones: el modelo estadístico valorado permite la tabulación de datos desde el laboratorio provincial de control de la calidad, a través de las variables propuestas y así evaluar a cada laboratorio


Introduction: the purpose of every quality control laboratory for the serological diagnosis of syphilis is to monitor the accuracy of test performance. Objective: to evaluate the proposal of a statistical model to tabulate the results of the laboratories involved in the quality control of the veneral disease research laboratories-rapid plasma reagin serology for the assessment of and customized attention to them. Methods: a model for the collection of information from the 21 laboratories of Villa Clara's provincial network in the 2006-2010 period was designed and refined until the final version was reached. The defined variables comprised Number of sent sera, Total discordant, Nonreactive Discordant, Reactive Discordant, Shipping by month and Final evaluation were defined. Evaluation criteria were set for each variable. This paper presented the evaluation of the model with information from January to March, 2011. Results: the suggested model allowed the detection of the main difficulties such as the non-compliance with the number of sent sera, non-reception of samples monthly and also current conflicting results. The model is fair when making evaluation, since it uses generalized quantitative criteria that enable individualized qualitative assessment and it is also in line with current evaluative techniques applied in different fields of social endeavor. Conclusions: the statistical model allows provincial quality control laboratory to tabulate data by using the suggested variables and thus evaluate each laboratory in Villa Clara


Subject(s)
Humans , Male , Female , Models, Statistical , Syphilis Serodiagnosis/methods , Quality Control
SELECTION OF CITATIONS
SEARCH DETAIL